13. Troubleshooting
Fault
The compressor does not start.
The compressor starts but
there is no pressure.
The compressor starts, pres-
sure is shown on the pressure
gauge, but the tools do not
start.
26 | GB
Possible cause
No supply voltage.
Insufficient supply voltage.
Outside temperature is too low.
Motor is overheated.
The non-return valve leaks.
The seals are damaged.
The hose connections have a leak.
A quick-lock coupling has a leak.
www.scheppach.com
Remedy
Check the supply voltage, the power
plug and the socket-outlet.
Make sure that the extension cable is
not too long. Use an extension cable
with large enough wires.
Never operate with an outside temper-
ature of below +5° C.
Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
Have a service center replace the
non-return valve.
Check the seals and have any
damaged seals replaced by a service
center.
Check the compressed air hose and
tools and replace if necessary.
Check the quick-lock coupling and
replace if necessary.