Service information
With this product, it is necessary to note that the follow-
ing parts are subject to natural or usage-related wear,
or that the following parts are required as consumables.
Wearing parts*: Carbon brushes, saw blade, batteries,
table inlays, dust collection bags, V-belts
* may not be included in the scope of supply!
Spare parts and accessories can be obtained from our
service centre. To do this, scan the QR code on the
cover page.
11. Storage
Store the device and its accessories in a dark, dry and
frost-free place that is inaccessible to children. The op-
timum storage temperature lies between 5 and 30 ˚C.
Store the power tool in its original packaging.
Cover the electric tool to protect it from dust or mois-
ture.
Store the operating manual with the power tool.
12. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomer's mains connection as well as the exten-
sion cable used must also comply with these reg-
ulations.
Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
Damaged electrical connection cable.
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the designation "H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
AC motor:
The mains voltage must be 220 - 240 V~.
• Extension cables up to 25 m long must have a
cross-section of 1.5 square millimetres.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Data of motor type plate
Connection type X
If the mains connection cable of this device is dam-
aged, it must be replaced by a special connection ca-
ble which can be obtained from the manufacturer or
its service department.
13. Disposal and recycling
N
otes for packaging
Notes on the electrical and electronic equipment
act [ElektroG]
Waste electrical and electronic equipment
does not belong in household waste, but
must be collected and disposed of sepa-
rately!
www.scheppach.com
The packaging materials are recy-
clable. Please dispose of packag-
ing in an environmentally friendly
manner.