The Hebefix 100 tank is a drainage pump
station which can be equipped with the
pumps U3KS, U3KS spezial, U5KS, U6K
ES+DS, US 62 up to US 103 ES+DS. The
operating conditions according to the
manual of the pump must be observed.
ATTENTION! The Hebefix is designed
for usual domestic drainage water, ac-
cording to EN 12056. In some countries
it must not be used for pumping sewage
water from lavatories.
The allowed temperature of the pumped
medium is 35° C (short time period 60° C).
The Hebefix 100 has 4 lateral marked
connection branches on both sides for
tubes with Ø 50 mm or Ø 110 mm to
connect a wash basin, a washing ma-
chine or a dishwasher. In connection
with a special float a shower can be
connected as well. The pressure tube
can be installed right or left handed
through the upper connection pieces of
the tank casing. The marked opening
has to be drilled at site.
The tank is serially fitted with a venti-
lation valve in the lid, which closes with
rising water level. If the marked con-
nection in the cover will be opened, the
vent pipe to the roof can be connected
from the top. Alternatively it can be con-
nected at the side, in this case, ventila-
tion valve can be closed with the closing
plug ø22,3.
Ventilation.
Sumps and tanks for the drainage of a
cellar should be covered and, if neces-
sary, specially ventilated (EN 12056).
Ventilations with additional activated
carbon filters decrease annoyance
caused by bad smell.
Extent of delivery
Above ground tank Hebefix 100 (tank
with sealed screwed lid), 1 hose clamp,
2 fillister head screws, 3 cap screws , 3
caps (black), 1 ball Ø 25,4 mm, socket
plug DN 50, 1 ventilation seal, 1 plug-in
seal d 50 x D59, 1 activated carbon filter,
1 closing plug.
Bag with: bushing 50x1½", 2 octagon
nuts, 2 PE-bearing rings, threaded bus-
hing, connection joint, 2 elbows 90°, 2
pipes ø 50x100, elastic connection 1½",
2 hose clamps 1½", bushing 40x1¼", 4
plug-in seals d50 x D59, closing plug
ø22,3, 2 wood screws, 2 washers 2
plugs, 2 fastening clamps, 2 fillister
head screws.
Bag with : 1 non-return valve DN 40, 1
collar DN 100, 2 hose clamps 4", 1 ma-
nual.
ELECTRICAL
CONNECTION
Please pay attention to the operating in-
structions of the installed pump.
MOUNTING
The installation of the lifting unit should
be made in accordance to the guide li-
nes for faeces free sewage EN 12056-4.
The tank must be easily accessible for
maintenance and service. The installa-
tion must guarantee the reliable opera-
tion.
The Hebefix 100 should be installed as
shown at the end of the manual. In ac-
cordance to EN 12056 the pressure pipe
must be taken in a loop over the local
back-up level and secured with a reflux
valve. The reflux valve1 ½ inch (Z-53.4-
369) is enclosed. Each drain connection
(e.g. washing machine, dish washer ...)
must have a siphon trap.

Installation

1. Take the plugs and the screws out of
the cable cover. Remove the cover itself.
Seize into the recessed grips, lift the
cover off the tank and withdraw the ac-
cessories.
U3KS, U5KS and U6KS: Screw the 1¼"
plastic elbow (extend of pump unit) with
sealing tape handtight onto the pres-
sure branch of the pump. Screw the re-
ducing nipple 40 x 1¼" into the elbow.
US 62 bis US 103 ES+DS: Screw one of
the 1½" plastic elbow with pipe piece Ø
50 x 100 with sealing tape into the pres-
sure branch of the pump.
Next, component follows the elastic
connection. For the further pressure
pipe construction see drawing page 2.
2. Open the required connection pie-
ces for the pressure outlet, the inlet(s)
and if required for the ventilation at the
marked points, by cutting or drilling.
ATTENTION! Do not damage the raised
and flat face ! and push the enclosed
ENGLISH
plug-in seals into the opened connec-
tion branches.
Connection of the inlet pipe DN 100:
connect the spigot end of the DN 100
pipe with the elastic connection DN 100
and the 2 hose clamps 4" to the required
tank socket. For additional connections
in DN 100 elastic connections and hose
clamps are available as accessories.
3. Put the pump with the pressure pipe-
work into the floor lock of the tank and
push the pressure tube through the
bore hole. Fasten the pipework with the
1½" octagon nut from outside. The tank
can now be connected with the external
pipework.
4. Pull the pump cable with the plug
through the Ø 70 mm hole in the cover.
Swing open the
seal plug, insert
the pump cable
and
plug
provided hole in
the cover. The
cable in the tank
must be so short
that the float moves free. For the outer
cable lenght think about the installation
of the cover and necessary maintan-
ance.
5. Remove and unwrapp the activated
carbon filter and put it over the ventila-
tion hole between the terminal plates.
In case of ventilation to the roof press
the enclosed plug into the ventilation
hole of the lid.
6. Press the cover over the tank edge
until the snap connections click into
place. Fix the cable(s) with the clips
and the screws. Screw down the cover
with the screws and cover them with
the plugs. Now the Hebefix is ready for
service.
Mounting special float (accessory)
The special float (JP 44795 or JP44207)
for the pump is required for dewatering
a shower tray. A shower can be connec-
ted only in conjunction with a dewate-
ring pump U3KS, U5KS or U6KS. To
prevent a backpressure of water into
the shower tub, observe the min. show-
er installation height.
In connection with a US pump type the
special float allows to lower the switch
levels, e.g. for washingmachines.
push
the
into
the
7