Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance - Jung Pumpen HEBEFIX 100 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

ENGLISH
Mounting automatic alarm (accesso-
ry)
The automatic alarm AGR (JP44893) or
the alarm AWR (JP44897) signalizes an
unacceptably high water level. The AWR
simultaneously turns off the connected
washing machine or dishwasher.
Open the marked position in the cover
Ø 13 mm and mount the alarm switch
corresponding to the operation instruc-
tions.
The installation of a U3KS, U5KS and
U6KS with a low level switch requires,
the fastener (JP28191) for the alarm
unit.

MAINTENANCE

Before every work on the
pump: pull main plug!
The unit is free of maintenance. In case
of a deteriorate pump performance re-
move all sediments from the tank.
For pump maintenance see manual of
the pump.
Change of the activated carbon filter
∙ 1x year at least
∙ in case of annoyance caused by bad
smell
∙ in case of water penetration through
the filter.
8

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis