Aqmos R2D2-32 Betriebsanleitung Und Programmieranleitung Seite 10

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 218
4
TIME
REG. TIME
5
REG. DAYS
6
(REGENERATION
DAYS)
7
REG. CAP.
METER
DELAY
METER
OVERRIDE
2:00
7
R2D2-32 = 1,45 To.
R2D2-48 = 2,10 To.
R2D2-72 = 3,20 To.
In this mode, the system regenerates
automatically after reaching a fixed, pre-
programmed water volume.
Regeneration occurs at a specified time
(delayed) after the set volume is
reached.
Abbreviation on the display:
MD (Meter Delay)
In this mode, the system regenerates
automatically after reaching a fixed, pre-
programmed water volume.
Regeneration occurs at a specified time
(delayed) once the set volume is reached.
Additionally, a forced regeneration is
triggered after a pre-determined number
of days, regardless of the water
consumption. This prevents bacterial
contamination of the system when no
water is used (e.g., during vacations).
Abbreviation on the display:
MO (Meter Override)
Set time.
Enter the time at which the system
should regenerate. We recommend 2:00
a.m., as water usage is typically minimal
at that time.
Enter the number of days after which
the system should regenerate (only in
"Calendar Clock" and "Meter Override"
modes).
The softening capacity is specified here.
The capacity is calculated based on the
existing water hardness, the amount of
softening resin, and the desired blending
setting at the control valve.
You can find the value in chapter 12.