INSTALLATION AND SERVICE MANUAL FOR PROFESSIONALS
Annex: Technical data
Annex
Technical data
TECHNICAL DATA
Max. flow rate at 100Pa
Max. nominal flow rate at 100Pa V
Operating range passive house
@ 100 Pa
EN 13141-7 reference flow rate
@ 50 Pa
PERFORMANCE
Thermal efficiency according to
EN 13141-7 @ reference flow
Leakage (external and internal)
according to EN 13141-7
Filters according to EN 779:2012
Filters according to ISO 16890
Ambient temperature range for
the installation
Maximum humidity level in the
extract air
Outside air temperature range
(without preheating coil in-
stalled)*
Outside air temperature range
(with preheating coil installed)
CABINET
Dimensions (with bracket)
Spigot / air duct connections
Weight
Thermal conductivity of the
polystyrene insulation
Heat transfer coefficient of the
polystyrene insulation
Drain hose (included in scope of
delivery)
Cabinet colour
Fire protection class of the poly-
styrene insulation according to
DIN 4102-1
Fire protection class of the poly-
styrene insulation according to
EN 13501-1
Abbr.
Unit
RCV 320 P1
3
V
m
/h
320
100Pa
3
m
/h
200
max.nom
3
VPHI
m
/h
71 to 162
3
Vref
m
/h
140
η
%
94
SUP
%
< 2 % (class A1)
-
G4 (optional on
supply air: F7)
-
ISO Coarse
(ePM1>50 % op-
tional on supply
air)
t
°C
-12 to +45
SURR
x
g/kg
10
t
°C
-12* to +40
ODA
t
°C
-20 to +40
ODA
WxHxD
mm
600 x 603 x 548
Ø
mm
Ø125 – female**
m
kg
32
λ
W/(mK)
0.031
U
W/
U<1
(m2K)
Ø -
"-m
3/4" – 1 m
length
RAL
-
no paint/
galvanised steel
-
B2
-
RCV 320 P2
320
200
140
95
< 2 % (class A1)
G4 (optional on
supply air: F7)
ISO Coarse
(ePM1>50 % op-
tional on supply
air)
-12 to +45
10
-12* to +40
-20 to +40
600 x 603 x 548
Ø125 – female**
32
0.031
U<1
3/4" – 1 m
no paint/
galvanised steel
B2
E
E
57