LCD
Description
Display
Seat sensor icon is displayed on
the LCD.
PTO Switch icon blinks.
Steering lever icon blinks.
Energy recovery icon blinks
occasionally.
OFF
Charging Port Fault
FAULT CODE REFERENCE
Description
Left blade motor fails in rotation
Right blade motor fails in rotation
NOTICE: For any other fault codes appeared on the LCD screen, which may indicate PCBA failure, loosen connection, motor failure of the driving
motor, blade motors, etc., please remove all battery packs and re-insert them a few minutes later to restart the mower. If this doesn't solve the
problem, please record the fault code and contact EGO customer service center for repair.
WARRANTY
EGO WARRANTY POLICY
Please visit the website egopowerplus.eu for full terms and conditions of the EGO Warranty policy.
Mower
Status
Beeper
Cause
Indicator
The operator leaves
OFF
No
the seat or seat switch
is dis- connected.
The blade motor
was interrupted in
OFF
No
operation and the PTO
switch is not set to off
position.
The driving motor
was interrupted in
OFF
No
operation and the
steering levers are not
set to open position.
The kinetic energy
generated during
braking or driving
OFF
No
downhill is converted
into electricity to
charge the battery
packs.
There is no power
Solid RED
n/a
supply.
Electronic faults, such
as the charging port
Solid RED
n/a
is in open circuit, the
fuse is blown, etc.
Fault Code on LCD
Audio Indicator
509
One beep
609
One beep
Solution
If with the operator seated on the seat
, the icon is on, stop operating the
mower immediately and check the seat
connection. If the seat connection with
the mower is confirmed correct, please
contact a qualified service technician for
repairs.
Before restarting the mower, push
the PTO switch downward to
disengage the deck motor. Please see
"TROUBLESHOOTING" section in this
manual for reference.
Before restart the mower, move the
steering levers to the open position.
Please see "TROUBLESHOOTING"
section in this manual for reference.
This is normal operation. No action is
needed.
Check the wall outlet whether there is
220V-240V supplied or the socket is
good.
Contact EGO customer service center for
repair.
Solution
Inspect the blade first. If it is loosened,
tighten the bolt with recommended
torque. Otherwise, Please contact EGO
customer service center for repair.
ZERO TURN RIDE-ON MOWER — ZT5200E-L
EN
35