• Afterwards, close the oil drain plug (m)
again.
• Remove the ventilation cap, pour in 7 litres
of fresh hydraulic oil using a clean funnel.
• Replace the ventilation cap.
Dispose of the used oil in a correct man-
ner at a public collection facility. It is
prohibited to drop old oil on the ground
or to mix it with waste.
We recommend oil from the HLP 32 range.
Splitting spar
Before use, the spar of the splitter must
be slightly greased. Repeat this procedure
every five operating hours. Slightly apply
grease of oil spray. The spar may never run
dry.
Hydraulic system
The hydraulic unit is a closed system with
oil tank, oil pump and control valve.
The system is complete when the machine
is delivered, and may not be changed or
manipulated.
Regularly check the oil level.
Too low an oil level damages the oil pump.
Regularly check the hydraulic connections
and bolts for tightness. Retighten if neces-
sary.
Before undertaking any maintenance or
checking work, the working area must be
cleaned. Keep the necessary tools within
the reach of your hand.
The intervals mentioned herein are based
on normal conditions of use. An excessive
use of the machine shortens the intervals
accordingly.
Clean the panels, screens and control le-
vers with a soft cloth. The cloth should be
dry or slightly humid with a neutral cleaning
agent. Do not use any solvents like alcohol
or benzene as they could damage the sur-
faces.
Store oil and grease outside the reach of
unauthorized personnel. Strictly follow the
instructions on the bins. Avoid direct contact
with the skin. Rinse well after use.
Service information
Please note that the following parts of this
product are subject to normal or natural
wear and that the following parts are there-
fore also required for use as consumables.
Wear parts*: Splitting wedge, Splitting
wedge extension, splitting wedge guides,
hydraulic oil, splitting cross, splitting fan,
Splitting wedge widening
* Not necessarily included in the scope of
delivery!
GB