Rocksmart RSC600 User Manual
When set as [Enabled], user can make further settings in the following items:
Device Settings
Change Settings
Use this item to select an optimal setting for Super IO Device.
The optional settings: [Auto]; [IO=3F8h; IRQ=10;]; [IO=2F8h; IRQ=10;]; [IO=3E8h; IRQ=10;]; [IO=2E8h;
IRQ=10;]; [IO=2F0h; IRQ=10;]; [IO=2E0h; IRQ=10;]; ► Serial Port 5/ Serial Port 6 Configuration
Press [Enter] to make settings for the following items:
Serial Port
Use this item to enable or disable Serial Port (COM).
The optional settings: [Disabled]; [Enabled].
When set as [Enabled], user can make further settings in the following items:
Device Settings
Change Settings
Use this item to select an optimal setting for Super IO Device.
The optional settings: [Auto]; [IO=3F8h; IRQ=11;]; [IO=2F8h; IRQ=11;]; [IO=3E8h; IRQ=11;]; [IO=2E8h;
IRQ=11;]; [IO=2F0h; IRQ=11;]; [IO=2E0h; IRQ=11;];
ERP Support
Use this item to select Energy-Related Products function. This item should be set as [Disabled] if you wish
to have all active wake-up functions.
The optional settings: [Disabled]; [Enable].
Case Open Detect
Use this item to detect case has already open or not, show message in POST. When set as [Enabled],
system will detect if COPEN has been short or not (refer to JPCLR jumper setting for Case Open
Detection; if Pin 7&8 of jumper JPCLR are short, system will show Case Open Message during POST).
WatchDog Reset Timer
Use this item to enable or disable WDT reset function.
The optional settings: [Disabled]; [Enable].
When set as [Enabled], the following sub-items shall appear:
WatchDog Reset Timer Value
User can select a value in the range of [10] to [255] seconds when 'WatchDog Reset Timer Unit' set as
[Sec]; or in the range of [1] to [255] minutes when 'WatchDog Reset Timer Unit' set as [Min]. WatchDog
Reset Timer Unit
The optional settings: [Sec.]; [Min.].
WatchDog Wake-up Timer
Use this item to enable or disable WDT wake-up function.
The optional settings: [Disabled]; [Enable].
When set as [Enabled], the following sub-items shall appear:
WatchDog Wake-up Timer Value
User can select a value in the range of [10] to [4095] seconds when 'WatchDog Reset Timer Unit' set as
[Sec]; or in the range of [1] to [4095] minutes when 'WatchDog Reset Timer Unit' set as [Min]. WatchDog
Wake-up Timer Unit
The optional settings: [Sec.]; [Min.].
ATX Power Emulate AT Power
This item support Emulate AT power function, MB power On/Off control by power supply. Use needs to
select 'AT or ATX Mode' on MB jumper at first (refer to AT_MODE jumper setting Pin 1&2 of for ATX Mode &
Pin 2&3 of AT Mode Select).