Safety Instructions

Personnel qualification

The device may only be operated by qualified persons.
The device may only be operated by individuals who have been instructed in its
proper use by qualified persons.
The device may only be operated and maintained by persons who are of legal age.
Other personnel may only work with the unit under continuous supervision of an
experienced qualified operator.
This manual must be read and understood by all persons working with the device.
The personnel must receive special safety instructions in order to guarantee respon-
sible and safe work procedures.

Operating company's obligations



Installation site

The device must be positioned in a suitable location.
The device must be installed on a firm and stable surface.
All screw connections must be securely tightened.
Do not operate the device in proximity of highly inflammable and explosive substances.
Installation and operation of the device is only permitted in facilities which are
equipped with appropriate laboratory equipment (e.g. with extractor hoods).
Only operate the device in conjunction with an extractor hood (at least 10-fold air
change, with error monitoring), if working with potential harmful media (see DIN EN
14175 and DIN 12924).
The device may only be operated in enclosed spaces and under the following environ-
mental conditions:
Ambient temperature
Installation altitude
Degree of pollution
Overvoltage category
If the equipment is used in corrosive atmospheres, the service life of the equipment
will decrease based on concentration, volumes, and frequency of exposures to these
corrosive materials, for example concentrated Hydrochloric Acid (HCl).

Changes to the unit

No unauthorized changes may be made to the unit.
No parts may be used which have not been approved by the manufacturer.
Unauthorized changes result in the EC Declaration of Conformity losing its validity,
and the unit may no longer be operated.
The manufacturer is not liable for any damage, danger or injuries that result from
unauthorized changes or from operating the unit other than as described in this
manual.
5 - 31 °C at 80 % relative humidity
32 - 40 °C decrease linearly
till max. 50 % relative humidity
0 - 2,000 m (6,500 feet) height above sea level
2
II
7