7.2. GENERAL CHARACTERISTICS
Reference guidelines
Safety:
EMC:
Insulation:
Pollution degree:
Measurement category:
Display
Characteristics:
Over range indication:
Conversion mode:
Power supply
Battery type:
Low battery indication:
Auto Power OFF:
Mechanical characteristics
Dimensions (L x W x H):
Weight (including battery):
Mechanical protection:
Environmental conditions
Reference temperature:
Operating temperature:
Operating humidity:
Storage temperature:
Storage humidity:
Max height of use:
This instrument satisfies the requirements of Low Voltage Directive
2014/35/EU (LVD) and of EMC Directive 2014/30/EU
This instrument satisfies the requirements of European Directive
2011/65/EU (RoHS) and 2012/19/EU (WEEE)
7.3. ACCESSORIES
7.3.1. Standard accessories
•
Plastic protection of metal probes
•
4mm metal sleeves adapter + tip protection, 2px
•
Batteries (not fitted)
•
Carrying case
•
User manual
38
IEC/EN61010-1, IEC/EN61243-3:2014
IEC/EN61326-1
double insulation
2
CAT III 1000V, CAT IV 600V
3½ LCD (1999 counts), decimal point
unit symbol, backlight
symbol "OL" on the display
Mean value
2x1.5V batteries type AAA LR03
symbol "
"on the display
after 1 minute of idleness (R measure)
270 x 70 x 30mm (11 x 3 x 1in)
290g (10ounces)
IP64
23°C ± 5°C (73°F ± 41°F)
-10°C ÷ 55°C (14°F ÷ 131°F)
<85%RH
-10°C ÷ 60°C (14°F ÷ 140°F)
<85%RH
2000m (6.562ft)
HT10
Cod. KITHT10