Make a note of the regeneration counters in the operating manual.
Make a note of the fault memory entries in the operating manual.
For the following maintenance steps, it is necessary to partially dis-
mantle the NeoSoft 2500 Connect.
Close the lever of the bypass valve to bypass the water softener.
Make sure that the flush line is still connected to the drain funnel before
starting the pressure relief of the water softener.
The system relieves all pressurized parts.
Pull out the mains plug.
The bypass valve with the flexible hose remains at
the top of the installation.
Assembly, commissioning, operation and maintenance NeoSoft 2500 Connect