Trouble shooting
LED displays
LED
green
blue
red
white
yellow
cyan
magenta
1
Fig. 9: LED
6 Trouble shooting
The MSA213C features diagnostic measures which are able to detect and
report to the drive control system any internal errors as well as errors that
occurred during mounting/installation.
Below are some typical errors which may occur during installation and
operation:
MSA213C-SA02 · Date 02.08.2022 · Art. No. 90917 · Mod. status 167/22
(Fig.
9)
Description
Sensor ready for operation
Senor/band distance warning
Error (sensor plausibility error/internal power sup-
ply faulty)
Service mode
Interpolator adjustment
Bootup indication
Hall adjustment
Magnetic tape wrongly mounted, active side below (see chapter 4.2).
The masking tape provided was not used for protecting the magnetic
tape. The masking tape must not be magnetizable.
Magnetic sensor not or incorrectly connected (pin assignment see
chapter 4.4).
The distance tolerances were not observed over the whole measuring
Fig.
8).
length (see
Cable squeezed / interrupted / cut by sharp edges.
The magnetic sensor has been mounted with the active side turned
away from the tape (see
Magnetic sensor has not been aligned according to
The magnetic sensor was taken into operation without magnetic tape.
Fig.
8).