TROUBLESHOOTING
Fault cause
Gas smell
Leaking LPG is
extremely
flammable.
Can cause
explosions.
No LED display
Top LED display
flashes yellow
Top LED display
lights up yellow
permanently
RESTORATION
If the actions described in TROUBLESHOOTING do not lead to a proper restart and if there is
no dimensioning problem, the product must be sent to the manufacturer to be checked. Our
warranty does not apply in cases of unauthorised interference.
SHUT-DOWN
Close the gas supply and then the shut-off fittings of the connected consumer equipment.
When the LPG system is not in use, all valves must remain closed.
MAINTENANCE
Upon proper ASSEMBLY and OPERATION, the product is maintenance-free.
REPLACEMENT
If there is any sign of wear or if the product or parts thereof are damaged, it must be replaced.
When the product has been replaced, observe the steps ASSEMBLY, LEAK TESTING and
START-UP.
22 / 24
Action
Close the gas supply.
Do not use any electric switches.
Do not use a phone in the vehicle. No smoking
Ventilate rooms well.
Shut down the LPG system.
Contact a specialised company.
Activate remote display:
See START-UP
Check the cables (in particular the power supply).
Check contact (see page 6).
Still no LED display:
Send the Caramatic BasicControl back to the manufacturer.
Check the cables (page 7), close the gas cylinder valves, interrupt
the power supply briefly to restart the remote display, open the gas
cylinder valves:
Top LED display no longer flashes yellow after this: ok
Top LED display flashes yellow after this, both LEDs A + B do
not light up, send the Caramatic BasicControl to the manufacturer.
The first time or repeated times that power is applied, this is
indicated by an LED test (all LEDs flash briefly).
Too high pressure between the regulators A and B:
Open the shut-off fittings on the connected consumer
equipment. If no pressure compensation is achieved, if the LED
continues to light up yellow: Send the Caramatic BasicControl to
the manufacturer.
Caramatic BasicControl
Artikel-Nr. 71 392 50 b