Resistance
Range
60.0 Ω*
600.0 Ω*
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
60.00 MΩ
Overload protection 1000 V
Measuring voltage: approx. -0.5 V, measuring current approx. -0.7 mA
*Accuracy after deduction of the measuring line resistance
Capacity
Range
6.000 nF*
60.00 nF*
600.0 nF*
6.000 µF*
60.00 µF
600.0 µF
6.000 mF
60.00 mF
Overload protection 1000 V
*Accuracy for measurement range ≤ 1 µF only valid with the REL function used
Frequency "Hz" (electronic)
Range
600 Hz - 6.000 kHz*
60.00 kHz
600.0 kHz
6.000 MHz
40.00 MHz
Signal level (without direct voltage share):
≤100 kHz: 200 mV - 30 Vrms
>100 kHz - <1 MHz: 600 mV - 30 Vrms
≥1 MHz - <10 MHz: 1 V - 30 Vrms
10 MHz -40 MHz: 1.8 V - 30 Vrms
*The frequency measuring range starts at 600 Hz
66
Resolution
0.01 Ω
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Resolution
0.001 nF
0.01 nF
0.1 nF
0.001 µF
0.01 µF
0.1 µF
0.001 mF
0.01 mF
Resolution
0.001 kHz
0.01 kHz
0.1 kHz
0.001 MHz
0.001 MHz
Accuracy
±(1.3% + 3)
±(1.3% + 3)
±(1.0% + 3)
±(1.6% + 4)
±(3.0% + 7)
Accuracy
±(4% + 13)
±(4% + 7)
±13%
Accuracy
±(0.1% + 5)