2.5. Reset to default settings
▸
Disable the camera's power supply
(Disconnect camera from PoE supply)
▸
press and hold
Open the camera cover very carefully
beforehand. (See note on page 25)
▸
Press and hold the reset button (network
boot) and restore the power supply (PoE).
(See also photo)
▸
Press and hold the reset button for about 15 to
30 seconds until the status LED flashes yellow
▸
Release the reset button. The process is com-
plete when the status LED lights up green.
The product has been reset to the default set-
tings. If no DHCP server is available in the net-
work, the standard IP address is 192.168.0.90.
The following settings must be restored after
reset:
For 20-2940A-IP/21-2940A-IP, 21-2941A-IP/
21-2941A-IP, 50-2940A-IP/43-2940A:
▸
1. Assign camera password
▸
2. Capture Mode: 4MP (2304x1728)
▸
3. Powerline frequency 50 Hz
▸
4. System/Simple set-up/Network/ set HTTP to
„Basic"
▸
5. System/Simple set-up/Network/ ZeroConf:
Remove the tick next to „Enabled"
!
These settings should only be made if
you have sufficient knowledge of the
AXIS web frontend.