Attention!
The following materials come into contact with the liquid:
stainless steel, ETFE, FFKM, FKM, EPDM, ceramic, Teflon coal
according to the design.
Safety instructions
Attention!
Drive by
Commutator motors
Compressed air-motors:
5.1
Compressed-air motor F 416 Ex, F 416-1 Ex, F 416-2 Ex
Before connecting the air supply hose to the motor, set the Start/Stop switch
to "0" (Stop)
n model F 416 Ex unlock locking mechanism of the on/off switch).
(o
Use a silencer or an exhaust hose.
Air consumption F 416 Ex, F 416-1 Ex, F 416-2 Ex :
at 3 bar operation pressure ~ 7 l/sec.
at 6 bar operation pressure ~14 l/sec.
Observe the resistance to the liquid.
Before using the pump, check the coupling for smooth operation.
Check the coupling on the pump and the driver at the motor by
visual inspection for wear.
If damaged, replace coupling and driver. Use only original spare
parts by FLUX.
Observe the operating instructions of the motors and pumps.
FEM 4070, F 457, F 457 EL, F 458, F 458 EL, F 458-1
In hazardous areas:
F 460 Ex, F 460 Ex EL, F 460-1 Ex, FBM 4000 Ex
F 416 Ex, F 416-1 Ex, F 416-2 Ex
MINIFLUX