Proceed as follows for installation:
1. Place the stove onto one of its sides taking care that the
internal baffles and the brazier do not fall out of their housing.
2. Position the fan plate and fasten it with the screws provided.
3. Insert the PT probe in the special ø8mm hole so that it passes
within the probe holder conduit for nearly 30cm and fix it in
place with the fastening bracket to the fan support (Pic.1).
4. Bring the monobloc unit to its normal position.
5. For possible or additional outlets to heat adjoining rooms,
branch lines can be laid from the flexible hose with the special
Y-union (provided upon request by PIAZZETTA S.p.A.);
remove the semi-sheared openings from the rear protective
panel, then insert the flexible hose.
If air is also to be conducted to adjoining areas, select the
shortest path, thus limiting the dispersion of heat.
It is therefore recommended that the flexible hose not be laid
in excessively long paths and that it be insulated as best as
possible. (See the instructions attached to the stove) (Pic.7).
Upon request, PIAZZETTA S.p.A. will provides the flexible
Ø75 conduit, air outlets, "Y-unions" and the conduit-tightening
bands for fastening.
6. Insert the panel plug in the slot located in the rear part of the
stove with the central pin facing upwards (Pic.1).
7. Make the electrical connection to the panel plug inserting the
grounding clip (yellow-green wire) on the upper central pin of
the three present (Pic.2).
8. Next connect the power cord provided to the panel plug
(Pic.2) and insert it in the electrical outlet.
KEY
1. FAN
2. RADIO CONTROL BOX
3. RADIO CONTROL UNIT
4. PT PROBE
5. PT PROBE FASTENING BRACKET
6. FAN SUPPORT PLATE
7. FLEXIBLE CONDUIT D. 75
8. HOT-AIR EXHAUST OUTLET
9. CLOSABLE HOT-AIR EXHAUST GRID
10. I.E.C. PLUG
38
2. INSTALLING VENTILATION KIT e900M
6
8
9
N.B.: Keep the radio control box far from heat
sources such as flexible conduit or metal parts
that could heat up positioning it beneath the
product
3
4
7
1
5
10
2