Faults
Indicator lamp
does not light up?
Ventilator does
not work?
Warning lamp
switches on?
No output
current?
Output current
does not
decrease?
Air flow cannot
be regulated?
HF-arc is not
created?
Bad
ignition?
Plasma burner
8
is not ready for
operation?
Sparks fly
upwards, instead
of down through
the material?
Initial cut but not
completely drilled
through?
18
GB/IE/NI/CY/MT
Cause of fault
No electrical connection.
ON/OFF switch set to off.
Power line interrupted.
Ventilator power line faulty.
Ventilator faulty.
Overheating protection
switched on.
Input voltage too high.
Machine faulty.
Overvoltage protection
activated.
Input voltage too low.
Connection cable cross-section
too small.
Compressed air hose
damaged or faulty.
Valve/manometer fails.
The burner switch is faulty.
Soldering point on the burner
switch or plug loosened.
Valve/manometer fails.
Burner wear parts damaged
or worn.
Current switch is switched off.
Air transmission is restricted.
Workpiece is not connected to
the earthing clamp.
Burner sleeve
8c
penetrate the material.
Burner sleeve
8c
away from the material.
Material was probably not
earthed properly.
Lifting speed is too quick.
Potential connection problem.
Troubleshooting
Check whether the device is
connected to the socket.
Set switch to ON.
Check whether the device is
connected to the socket.
Allow device to cool down.
Input voltage according to
type plate.
Machine must be repaired.
Allow device to cool down.
Observe input voltage
according to type plate.
New connection of the line.
Replace electrode.
Change wear parts.
Switch the current switch to
"on".
Another indication of this is
a green flame. Check the air
supply.
Check the connections.
Increase the current.
does not
Reduce the gap between the
burner sleeve
is too far
Check the connection for
correct earthing.
Reduce the speed.
Check all connections.
8c
and material.