Difficulty starting engine, or engine will not start:
∙ "EMERGENCY STOP" actuated (visual and acoustic signal)
∙ Out of fuel
∙ Wrong fuel (diesel or two-stroke fuel)
∙ Soiled or old fuel (observe when filling fuel cans)
∙ Battery voltage too low
∙ Damaged high-pressure pump
∙ Oil fill level too high
∙ Dirt in fuel line
∙ Air filter soiled
∙ Faulty spark plug
∙ Wrong motor oil quality
∙ Starting under load
Engine stalls suddenly:
∙ Out of fuel
∙ Dirt in fuel line
∙ Soiled rotating cooling air intake filter
∙ Incorrect oil fill level
∙ Engine overload
∙ Air filter soiled
Insufficient engine power:
∙ Wrong fuel
∙ High temperature
EN
∙ Dirt in fuel line
∙ Soiled / clogged air intake and exhaust vents
∙ Incorrect oil fill level
∙ Engine overload
∙ Air filter soiled
∙ Faulty spark plug
∙ Incorrect valve play
Engine not running smoothly:
∙ Wrong fuel
∙ Dirt in fuel line
∙ Soiled rotating cooling air intake filter
∙ Engine overload
∙ Air filter soiled
∙ Faulty spark plug
Engine knocking:
∙ Wrong fuel
∙ Soiled rotating cooling air intake filter
∙ Engine overload
∙ Faulty spark plug