Herunterladen Inhalt Inhalt Diese Seite drucken

Rosenbauer RS 14 SUPER SILENT EFI Betriebsanleitung Seite 68

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Rosenbauer – RS 14 EFI & RS 14 SUPER SILENT EFI
On/off switch external refuelling
To activate/deactivate external refuelling, also see point 11 Operating mode
indicators.
Emergency stop
Use the Emergency Stop button in case of acute danger to quickly shut down
the power generator. The EMERGENCY STOP button must also be pressed
when servicing or performing maintenance work. This interrupts the engine's
ignition. After the danger has been eliminated, damage has been repaired or
the service and maintenance work has been completed, turn the EMERGENCY
STOP button to unlock. Also see point 10 Warning signals.
Grounding conductor test device
See Section 5.5.
Page navigation "next"
Switch between the display views.
Page navigation "back"
Switch between the display views.
Acknowledge button
To acknowledge messages on the display (faults & info messages).
10 WARNING SIGNAL INDICATORS
Charge indicator
Illuminated before the power generator starts. Once the engine has been
started and is running, the warning symbol disappears. If it is shown during
operations, the dynamo on the combustion engine, which is responsible for
charging, has failed or the starter battery is not being charged sufficiently
by the charge regulator in the vehicle. It is probable that the battery will be
drained and that the power generator will not be able to be power started. You
can continue to use the power generator in this case. Have the defect repaired
immediately after finishing operations.
Insulation error
This warning symbol is only active or activated if the power generator has an
"insulation monitoring" option and an insulation error has occurred.
68