power generator will not shut down. In this case, you must reduce the load on the
power generator.
∙ Voltage displays of the phases L1 L2 L3
Generator phase failure display
Over- or under-voltage display
0:3 h
ISO TEST
5SEC
L1
L2
236
225
0.0
10.0
0
1792
0.00
0.60
The multifunctional control panel and the control unit were designed to support safe,
functional and convenient operation of the RS 14 power generator. For your safety,
additional monitoring systems have been implemented, especially for temperature
monitoring. Values in excess of thresholds are indicated by warning symbols
opticalcally and/or acoustically.
We must point out that a warning only occurs in case of serious error, such as over-
heating of the power generator and that the unit must be shut down immediately.
Due to the rescue scenarios at emergency sites, the power generator will not shut
down automatically. It is the user's responsibility to decide whether to continue using
the power generator despite errors having occurred e.g. in order to complete a life
saving operation or to shut down the unit after the corresponding warning.
In this case, we cannot accept any claims under warranty or related to product
liability. This applies both to injury to persons and to damage to the power generator
itself.
The power generator operator is responsible for operating the unit with due care
and attention!
Service view
The service view displays the operating hours indicator
and test routine for the insulation error.
Expert view
The expert view displays the current status of the
L3
attached consumers with even more details. Voltage,
231
V
power, active power, and cosine phi are broken
0.0
A
down for each phase. What once required a separate
0
W
metering device is now visible directly on the device.
0.00
ø
This makes searching for the source of an error much
easier.
RS 14 EFI & RS 14 SUPER SILENT EFI – Rosenbauer