∙ The authorized personnel must follow the safety and work instructions of the
supervisors or safety officers.
∙ Absolutely no smoking within the hazard area of the power generator.
∙ The consumption of alcohol, drugs, medication or other conscious expanding or
altering substances is prohibited.
∙ Be aware of the increased noise level in the direct work area. If oral communication
is necessary keep your distance or communicate visually.
∙ When installing into a vehicle, the operating manual of the vehicle must be read.
∙ The power generator is state-of-the-art and meets the effective safety regulations
within the frame of its intended use at the time of introduction into the market.
∙ When designing the unit, it was not possible to avoid either foreseeable misuse or
residual hazards without limiting the intended functionality.
∙ Danger prevention is achieved by the special warning notices either directly on the
power generator and/or in the user's instructions.
Transport
∙ The power generator can only be transported when cold.
∙ When in the vehicle or equipment compartment the power generator must be
correctly locked and fastened (to the transport devices intended for this purpose).
∙ When transporting the power generator uncovered (trailer, etc.) attention must be
paid that all parts are especially secured against damage by wind (e.g. strap on an
extra belt for the cover, etc.)
∙ Be careful when transporting the power generator on uneven surfaces. The power
generator may only be lifted by the carrying handles.
∙ The power generator may only be carried by at least 4 people.
Set up
∙ Only set up the power generator on level and sufficiently firm ground.
∙ The maximum permissible angle of inclination in all axes is 15 °.
∙ Secure laid output connector cord(s) and if necessary cover with rubber mats.
∙ Avoid trip hazards by cables and fuel lines.
Operation
∙ The electrical safety must be checked before every operation.
∙ The power generator may not be covered during operation.
∙ The air inlet may not be obstructed or blocked.
∙ The consumers may not be plugged in or turned on when starting the power
generator.
∙ Only tested and approved cables may be used for the electrical power network.
∙ Do not make a connection between existing neutral conductors, equipotential bond-
ing conductors and/or equipment parts (safety-separated circuit).
∙ The total amount of power drawn may not exceed the maximum nominal output of
the power generator.
∙ When mounted to/in the vehicle or equipment compartment, the power generator
may only be run with the rollup doors and access step open.
∙ Never use exhaust heat from the engine for heating or drying purposes.