Place the lower end 2 hooks in the dedicated holes, reposition the top end two hooks
into the dedicated 2 holes. The screen filter will need to be bend a little, this must be
done by pressing on the top of the screen filter with 2 or 3 fingers.
If the green filter light stays on despite cleaning, reset the service time of 168 hours of use
indicating the cleaning of the filter. Simply press the "timer" button for 5 seconds while
the unit is in operation. The indicator light will flash 5 times, thus resetting the filter
service time. The green light goes out.
DRAINAGE OPTION
OPTION 1 EMPTYING MANUALLY
Notes:
• Do not remove the bucket when unit is in operation or has just stopped.
Otherwise it may cause some water to drip on the floor.
• Do not use the hose if using water bucket to collect water. When the hose is connected,
water will be drained out through it instead of into the bucket.
1
Hold the handle at the bottom of the water bucket and pull it out folllowing the
arrow direction.
2
Empty the bucket by grasping the handle on the bottom of bucket with one hand
and grasping the top of bucket with the other hand.
3
Replace bucket in the dehumidifier according to the arrow direction.
OPTION 2 GRAVITY DRAIN HOSE
1
Use the hose included in the packaging.
2
Remove bucket from the unit as instructed.
3
Thread the drain hose onto the nozzle and make sure it's securely locked.
4
Replace the bucket. Make sure the drain hose goes through the buckets drain hole
and is placed downward. Lead the hose to the floor drain and then cover the hole
with a lid. Note that drain hose should not be pressed, otherwise water can not be
drained out.