Herunterladen Diese Seite drucken

Scheppach BC-MP380-X Originalbetriebsanleitung Seite 24

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
• Be careful when adjusting the product and avoid trap-
ping fingers between the moving blade and rigid parts
of the device.
• Be particularly careful when mowing on yielding
ground, nearby rubbish tips, ditches and dykes.
• Avoid mowing in places where the wheels have trou-
ble gripping or mowing is unsafe in any other way.
• Watch out for traffic near a road.
DANGER
Risk of tripping!
Exercise particular caution when moving backwards
and pulling the product.
Before reversing, make sure there are no small children
behind you.
• The user must be adequately trained in the use, ad-
justment and operation of the machine (including pro-
hibited operations).
• Check the product regularly and make sure that all
start locks and push buttons are working properly be-
fore each use.
• Please note that improper maintenance, the use of
non-compliant spare parts, or the removal or modifica-
tion of safety devices can result in damage to the
product and serious injury to the person working with
it.
• Please note that the product's safety systems or
equipment must not be tampered with or deactivated.
Never remove any safety-related parts.
• Use only blades and accessories recommended by
the manufacturer. Use of other insert tools and acces-
sories may result in injury to the user.
• Always keep the product in good operating condition.
• It is necessary to take enough breaks to reduce noise
and vibration exposure.
Using and handling the cordless tool
a) Only charge the batteries with battery chargers
recommended by the manufacturer. A battery char-
ger that is suitable for a particular type of battery pos-
es a fire hazard when used with other batteries.
b) Only use the batteries in power tools that are de-
signed for them. The use of other batteries can lead
to injuries and a risk of fire.
c) Keep the unused battery away from paper clips,
coins, keys, nails, screws or other small metal ob-
jects that could cause a short-circuit between the
contacts. A short-circuit between the contacts of the
battery could result in burns or fires.
d) Liquid may leak from the battery if used incorrect-
ly. Avoid contact with it. In case of accidental con-
tact, rinse with water. If the liquid gets into your
eyes, seek additional medical attention. Leaking
battery fluid may cause skin irritation or burns.
e) Do not use a damaged or modified battery. Dam-
aged or modified batteries can behave unpredictably
and cause fire, explosion or injury.
f) Do not expose a battery to fire or excessive tem-
peratures. Fire or temperatures above 130°C may
cause an explosion.
24 | GB
g) Follow all charging instructions and never charge
the battery or rechargeable tool outside the tem-
perature range specified in the operating manual.
Incorrect charging or charging outside the approved
temperature range can destroy the battery and in-
crease the risk of fire.
h) Never attempt to service damaged batteries. Any
type of battery maintenance shall be carried out only
by the manufacturer or an authorised customer ser-
vice centre.
Residual risks
The product has been built according to state-of-the-
art and the recognised technical safety rules. Howev-
er, individual residual risks can arise during opera-
tion.
• Damage to hearing if the stipulated hearing protection
is not worn.
• Residual risks can be minimised if the "Safety Instruc-
tions" and the "Intended Use" together with the oper-
ating manual as a whole are observed.
• Use the product in the way that is recommended in
this operating manual. This is how to ensure that your
product provides optimum performance.
• Furthermore, despite all precautions having been met,
some non-obvious residual risks may still remain.
WARNING
This power tool generates an electromagnetic field
during operation. This field can impair active or passive
medical implants under certain circumstances. In order
to prevent the risk of serious or deadly injuries, we rec-
ommend that persons with medical implants consult
with their physician and the manufacturer of the medical
implant prior to operating the power tool.
WARNING
In case of extended working periods, the operating per-
sonnel may suffer circulatory disturbances in their
hands (vibration white finger) due to vibrations.
Raynaud's syndrome is a vascular disease that causes
the small blood vessels on the fingers and toes to
cramp in spasms. The affected areas are no longer
supplied with sufficient blood and therefore appear ex-
tremely pale. The frequent use of vibrating products can
cause nerve damage in people whose circulation is im-
paired (e.g. smokers, diabetics).
If you notice unusual adverse effects, stop working im-
mediately and seek medical advice.
ATTENTION
The product is part of the 20V IXES series and may on-
ly be operated with batteries of this series. Batteries
may only be charged with battery chargers of this se-
ries. Observe the manufacturer's instructions.