Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage regu-
larly. Ensure that the connection cables are disconnected
from electrical power when checking for damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the designation H05RN-F.
The printing of the type designation on the connection
cable is mandatory.
Connection type Y
If it is necessary to replace the mains connection ca-
ble, this must be done by the manufacturer or their rep-
resentative to avoid safety hazards.
12. Cleaning
m Attention!
Disconnect the mains plug before carrying out any
cleaning work.
General cleaning tasks
• Non-stationary installed devices: Clean the pump
with clean water after each use.
• Stationary installed devices: Check the function of the
float switch (4) regularly (at least every three months).
• Remove lint and fibrous particles that may have be-
come trapped in the pump housing with a water jet.
• Regularly remove sludge from the base plate (6) (every
3 months at the latest) and clean the shaft walls.
• Clean the float switch (4) of deposits with clean water.
22 | GB
• If you have not used the pump for a longer period of
time, it must be cleaned thoroughly after the last use
and before its next use. Otherwise, start-up prob-
lems may occur due to deposits and residues.
Cleaning the filter
In order to protect the device and the pump impeller
from coarse contamination, there is an additional filter
in the suction strainer. Please proceed as follows to
clean the filter:
1.
You can remove the cover with the help of a screw-
driver.
2.
Remove the filter and wash it under running water.
3.
Then put the filter back into the suction strainer
and put the cover on.
13. Storage
Store the device and its accessories in a dark, dry and
frost-free place that is inaccessible to children. The op-
timum storage temperature lies between 5 and 30 ˚C.
Store the power tool in its original packaging. Cover the
power tool to protect it from dust or moisture. Store the
operating manual with the power tool.
14. Maintenance
Only carry out maintenance, cleaning and adjustment
work when the mains plug is pulled out.
The pump is largely maintenance-free. However, we
recommend regular inspections and care for a long
service life.
Connections and repairs
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the
event of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Engine data - type plate
Service information
With this product, it is necessary to note that the follow-
ing parts are subject to natural or usage-related wear,
or that the following parts are required as consumables.
Wearing parts*: Seals
* may not be included in the scope of delivery!