• Before each use, check the device, cables and con-
nectors for damage. Defective cables must not be
repaired but replaced with a new ones. Have dam-
age to your device repaired by a specialist.
• If the connection cable of this unit is damaged, it
must be replaced by the manufacturer or their ser-
vice department or a similar qualified person in or-
der to avoid hazards.
• Do not use the cable to pull the plug out of the out-
let.
• Protect the cable from heat, oil and sharp edges.
• Do not carry or fasten the device by the cable.
• Use only extension cables that are splash-proof
and intended for outdoor use. Always unroll a ca-
ble drum completely before use. Check the cable for
damage.
• Disconnect the mains plug from the socket before
carrying out any work on the device, as well as dur-
ing breaks in work and when not in use.
• Mains connection cables shall not have a smaller
cross-section than rubber hose lines with the desig-
nation H05RN-F. The cable length must be 10 m.
The conductor core cross-section of the extension
cable must be at least 1.5 mm
Lubricants are used inside the pump which may con-
taminate the liquids flowing out of the device if the de-
vice is operated improperly or damaged.
m Warning! This power tool generates an electro-
magnetic field during operation. This field can impair
active or passive medical implants under certain cir-
cumstances. In order to prevent the risk of serious
or deadly injuries, we recommend that persons with
medical implants consult with their physician and the
manufacturer of the medical implant prior to operating
the power tool.
6. Residual risks
The machine has been built according to the state-of-
the-art and the recognised technical safety require-
ments. However, individual residual risks can arise
during operation.
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
• Furthermore, despite all precautions having been met,
some non-obvious residual risks may still remain.
• Residual risks can be minimised if the "Safety In-
structions" and the "Intended Use" together with the
operating manual as a whole are observed.
20 | GB
.
2
www.scheppach.com
• Avoid accidental starting of the machine: the op-
erating button may not be pressed when inserting
the plug in an outlet. Use the tool attachment that
is recommended in this operating manual. This is
how to ensure that your machine provides optimum
performance.
• Keep your hands away from the working area when
the machine is in operation.
7.
Technical data
Device L x W x H
Mains power connection
Rated input
Max. delivery flow
Max. delivery height
Max. pump pressure
Max. water temperature
Protection category
Max. particle size
Weight
Subject to technical changes!
8. Unpacking
• Open the packaging and carefully remove the de-
vice.
• Remove the packaging material, as well as the pack-
aging and transport safety devices (if present).
• Check whether the scope of delivery is complete.
• Check the device and accessory parts for transport
damage. In the event of complaints the carrier must
be informed immediately. Later claims will not be
recognised.
• If possible, keep the packaging until the expiry of the
warranty period.
• Familiarise yourself with the device by means of the
operating manual before using for the first time.
• With accessories as well as wearing parts and re-
placement parts use only original parts. Spare parts
can be obtained from your specialist dealer.
• When ordering please provide our article number as
well as type and year of manufacture for your equip-
ment.
180 x 165 x 270 mm
230V~ / 50 Hz
350 W
5500 l/h
11 m
1.1 bar
35°C
IPX8
1 - 3 mm
3.8 kg