Technical specifications
Type
Rated power
Pressure loss*
bar / l/min
Rated capacity
Design
Rated overpressure
Weight
Safety class DIN EN 60335
Protection mode EN 60529
Mark of conformity
Approval of the German
building control
Water connection (male thread)
Electrical connection
Free of system interference as per
Heating system
Application area
Application areas specific electrical
resistance / conductivity
Flow rate „on"
Flow rate „off"
Tab. 2
* Pressure loss figures also apply to the minimum flow pressure to DIN 44851/flow rate
for heating from 10 °C to 60 °C (∆ϑ 50 K). A pressure loss of 1 bar is recommended
for pipe network design, in line with DIN 1988, Part 3, Table 4.
Application areas for instantaneous water heaters relative to the specific
electrical conductivity / specific electrical resistance of the water
Type
Designation as
DHE
specific electrical
resistance
corresponding to
specific electrical
conductivity
Tab. 3
* Note:
The values for the specific electrical resistance and the specific electrical conductivity are
determined at different temperatures in different regions. This must be borne in mind in
any evaluation.
** Application areas in solar mode (up to 55 °C) specific electrical resistance ≥ 1100 Ωcm.
(the data on the unit rating plate apply)
DHE 18
DHE 21
kW
18
21
0,6 / 5,2
0,8 / 6,0
l
0,4
closed (pressurized)
bar
kg
5;2
IP 25
see rating plate
G 1/2
3/PE ~ 400 V
IEC 1000-3-5 (EDIN VDE 0838-5)
VDEW-license
Bare wire
Including hard water areas in particular
see Table 3
≥ 3,0 l/min
≤ 2,0 l/min
Application areas for various water analysis
reference temperatures*
standardized
version
at 15 °C **
at 20 °C
≥ 900 Ωcm
≥ 800 Ωcm
≤ 111 mS/m
≤ 125 mS/m
≤ 1110 µS/cm
≤ 1250 µS/cm
DHE 24
DHE 27
24
27
1,0 / 6,9
1,2 / 7,7
10
1
at 25 °C
≥ 735 Ωcm
≤ 136 mS/m
≤ 1360 µS/cm
Brief description
(for a qualified installer)
The DHE microcomputer-controlled, fully
electronic, instantaneous water heater is a
pressurized unit for heating cold water to
DIN 1988 or for further heating preheated
water up to 55 °C (solar mode).
The DHE's maximum inlet temperature
must not exceed 60 °C (higher tempera-
tures
on the display can damage
the unit).
Measures must be taken to ensure that
the inlet temperature of the DHE
does not exceed 60 °C
(e.g. by using special accessories, see
page 37).
One or more water taps may be supplied
by the unit.
If the selected outlet temperature cannot
be reached, because a fully open tap or
2nd tap requires more flow than the DHE
can heat, given its power rating, the flow
restriction valve - actuated by the micro-
computer - reduces the flow rate so that
the set temperature is always reached.
The specific electrical resistance of the
water must not be lower than
specified on the rating plate e.g.
Table 3!
If you have a combined water system, the
lowest electrical resistance of the water
should be used (see Tables 2 and 3). You
can obtain details of the specific electrical
resistance or the electrical conductivity of
the water from your water supply
company.
13