the selected value.
Indicator light B will stay on while the water is being heated. Once the selected water
temperature has been reached, the heating is disabled (indicator light B is turned off).
If the temperature drops, after water is drawn for example, the heating is re-abled
automatically.
On first lighting and following a power failure, the appliance will be set to the MIN
temperature setting. If on the other hand the appliance is turned off at button 1, it will
resume from the last temperature setting made when it is turned back on.
Use button 3 to enable the fast heating feature (FAST), indicator light D will light up
to notify you that the fast heating feature has been enabled.
Indicator lights E provide an indication as to the energy content of the appliance.
The appliance control panel was created to facilitate the various operations. For the
different adjustments, it indicates:
- the water temperature
- the quantity of showers or baths possible
We recommend you set the temperature of the water heater to 60°C to:
- reduce the formation of limescale;
- reduce heat dispersion;
- avoid the risk of bacteria proliferation.
When the appliance is powered (even if it is turned off), the anti-frost function is on.
Resetting the bipolar safety
In the event of an abnormal overheating of the water, a thermal safety switch in
compliance with CEI-EN norms cuts off the electrical circuit on both the power supply
phases of the heating element; in this case, call the After-sales service centre for
assistance.

USEFUL INFORMATION

If the water comes out cold
Have the following checked:
- that the thermostat terminals are powered;
- the thermostat thermal safety;
- the heating parts of the heating element.
If the water comes out boiling hot (steam in the taps)
Disconnect the appliance from the electricity supply and have the following checked:
- the setting and correct operation of the thermostat;
- the amount of limescale build-up in the tank and on the components.
Insufficient hot water supply
Have the following checked:
- the pressure of the water mains;
- he condition of the hot water inlet pipe;
- the electrical components.
Water trickling from the pressure safety device
During the heating phase, some water may trickle from the tap. This is normal. To
prevent the water trickling, a suitable expansion vessel must be installed on the flow
system.
If the trickling continues even after the heating phase, have the device calibration
checked.
DO NOT TRY TO REPAIR THE APPLIANCE UNDER ANY CIRCUMSTANCES:
ALWAYS CONTACT PROFESSIONAL STAFF.