UK
Antifreeze protection in the
winter
Low ambient temperature pro-
tection
Cooling condenser tempera-
ture too high protection
T2 water temp. Protection in
the cooling mode is too low
High pressure
Low pressure fault
No water flow
Overheating of the heating
function
154
The ambient temperature
PP07
or water inlet tempera-
ture is too low
The ambient temperature
PP08
or water inlet tempera-
ture is too low
The cooling condenser
PP10
temperature is too high
PP11
1. Too much refrigerant
EE01
2. Insufficient airflow
1. Insufficient refrigerant
EE02
2. Insufficient water flow
3. Filter jammed or capil-
lary jammed
Low water flow, wrong
EE03
flow direction, or flow
switch fault.
EE04
Low or no water flow
MV-1401-1402-1403-1404-01-2024 . © All rights reserved Swim & Fun ApS
Wait for the temperature to be
within the heat pump tolerance
Check or change the sensor.
Please create a complaint, your
heat pump needs to be serviced -
https://swim-fun.dk/en/support
Stop the heat pump and wait until
the temperature of the cooling
condenser drops.
1. Water pump
fault
2. Water pipe
Please create
blocked
a complaint,
3. Flow switch
your heat pump
blocked
needs to be ser-
1. Discharge
viced -
excess refrig-
https://swim-
erant from the
fun.dk/en/sup-
heat pump's gas
port
system
2. Clean the air
exchanger
1. Check if
Please create
there is any gas
a complaint,
leakage, re-fill
your heat pump
the refrigerant
needs to be ser-
2. Clean the air
viced -
exchanger
https://swim-
3. Replace the
fun.dk/en/sup-
filter or capil-
port
lary tube
Check if that the water supply
is sufficiently high and that it is
flowing in the right direction,
otherwise there may be a fault
with the flow switch.
Water pump fault
Blocked water pipe
Water flow sensor fault