UK
How parameter P3=1 works - always running.
When the heat pump turns on, the water pump starts, then the fan motor and and at last the com-
pressor. When the heat pump condition reaches T1≥Tset+1, it lasts for 3 mins. In that case the
compressor and fan motor will stop.
Time setting / Timer setting
Timer setting
Select the Timer setting menu A and press the settings button B, press
again B to enter the "Timer on/Timer off" setting.
Press the settings button B and C or D button to select "Timer on" or
"Timer off" setting (E).
Press the settings button B to select on or off state and press C or D to
set the time (E). Press E to save the setting.
Time setting
Press B for 5 seconds to set the current time (G).
8.
Maintenance
•
Regularly check the water flow to the heat pump. A water flow that is too low and the ingress of
air into the system should be avoided, as this will reduce the performance and reliability. You
should clean the pool/spa filter regularly to avoid damage caused by dirty or clogged filters.
•
The area around the heat pump should be dry, clean and well ventilated. Clean the sides of the
heat exchanger regularly to maintain a good thermal exchange and save energy.
•
Regularly check the power supply and connecting cable. If the unit starts to function abnormally
or any of the electrical components smell unusual, immediately turn off the heat pump and have
the relevant components replaced.
•
You must disconnect the water flow to the heat pump, if the heat pump will not be in operation
for a long period of time. Always check all parts of the unit and installation carefully before start-
ing it up again. Please also read section 9. Winter preparation.