Fitting the Harness

Some versions of the machine can be
carried on a harness.
The type and style of the harness
depend on the market.
Shoulder strap
2
Put on the shoulder strap (1).
N
Adjust the length of the strap so that
N
the carabiner (2) is about a hand's
width below your right hip.
HLE 71, HLE 71K

Connecting to Power Supply

The voltage and frequency of the
machine (see rating plate) must match
the voltage and frequency of the power
connection.
The minimum fuse protection of the
power connection must comply with the
specifications – see "Specifications".
The machine must be connected to the
power supply via an earth-leakage
circuit breaker to disconnect the power
supply if the differential current to earth
1
exceeds 30 mA.
The power connection must correspond
to IEC 60364 and relevant national
regulations.
Depending on the supply voltage and
cord length, the minimum conductor
cross section of the extension cord must
be as follows:
Cord length
220 V – 240 V:
up to 20 m
20 m to 50 m
100 V – 127 V:
up to 10 m
10 m to 30 m
N
Minimum cross
section
2
1.5 mm
2
2.5 mm
2
AWG 14 / 2.0 mm
2
AWG 12 / 3.5 mm
1
2
Plug the power cord (1) into the
coupling (2) of the extension cord
English