Taking the Wallbox eM4 Twin out of operation
In case of severe malfunctions or damage to the device, you must take the Wallbox eM4 Twin out of operation. To do
so, proceed as follows:
1 Unlock the side RCCB flaps using the key supplied
and flip them up.
2 Flip the toggle switches of both RCCBs to the
0 position.
3 Close the RCCB flaps again and lock them with
the key.
4 Open your domestic power distribution box,
disconnect the wallbox's power supply cable from
the electricity grid via the MCB, secure the MCB
against being switched on again and close the
distribution box.
The Wallbox eM4 Twin is no longer connected to the electricity grid and can be removed by a qualified specialist
electrical contractor if required.
Maintenance
Except for testing the integrated RCCBs, the eM4  Twin Wallbox is basically maintenance-free. However, we still
recommend the wallbox is cleaned and the charging sockets checked regularly:
Use only a dry cloth for cleaning the wallbox. Do not use aggressive cleaning agents, waxes or solvents (such as
x
cleaning fluid or paint thinner) as they may dull the status indicator and surface of the wallbox.