4 Check the status indicator of the wallbox.
If the charging operation has to be enabled
x
using an RFID card, a blue chase light is
shown dynamically on the status indicator.
Right-hand charge point
Left-hand charge point
5 Hold a valid RFID card in front of the status
indicator.
6 Check the status indicator and acoustic signals of
the wallbox.
If the RFID card has been read successfully,
x
the wallbox emits a short sound signal and
checks the authentication of the RFID card.
After successful authentication, the wallbox
x
emits two further short sound signals and
activates the charging operation.
If the authentication is not successful, the
x
status indicator lights up orange and the
wallbox emits three long sound signals.
NOTE
The authentication of the RFID card is not successful
If the RFID card could not be verified, do one of the following:
Remove the charging connector from the charging socket of the wallbox and wait until the status indicator
x
pulsates green again. Then repeat steps 2 to 6.
Operating the wallbox with a backend: Please contact the issuer of the RFID card.
x
Operating the wallbox without backend: Make sure that the RFID card has been registered to the rele-
x
vant wallbox. You can find further information in the comprehensive installation manual.