Battery Tester 043285
Test results tempering system
Assessment
STARTER
SPAN- NING OK
STARTER
VOLTAGE LOW
CHARGING BATTERY The starter voltage is low and the battery is
BATT. REPLACE
When you have completed a test with the battery installed, the display
content alternates between the battery test results and the message
PRESS ⮠ FOR GENERATOR TEST. Press when running-
the motor, press the ENTER key.
IMPORTANT: Check the generator belt before the test. If the belt is
shiny, worn or not sufficiently tensioned, the generator will not reach the
required speed for the test.
Charging system test
The display content alternates between the charging system assessment
and the peak output voltage of the generator.
Test results Charging system
Assessment
CHARGING
VOLTAGE OK
CHARGING
VOLTAGE NONE
The starter voltage is normal and the battery is
fully charged.
The starter voltage is low and the battery is fully
charged.
discharged. Fully charge the battery and repeat
the starter test.
If the battery test result is BATT. ERSET- ZEN
or CELL SHUTDOWN was displayed, the
battery must be replaced before the starter
test.
The generator output is within the normal range.
No problem has been detected.
The generator does not supply charging current to
the battery.
√ Check the V-belt to see i f the generator pulley
rotates. If necessary, replace a broken or
slipping belt and repeat the test.