6a)
Clack
6b)
Clack Clack
-
Clack
7a)
Clack Clack
-
Action
6) Changing the end limit settings
Note
End limit settings can only be changed using the master transmitter.
6a) Reducing the operating range (the desired end limit is within the possible
operating range)
Move to the desired new end limit.
First press the programming button and,
within 3 seconds, also press the EXTEND
button for the lower end limit or the RE-
TRACT button for the upper end limit and
keep both buttons pressed.
6b) Increasing the operating range (the desired end limit is outside the possible
operating range)
Move the curtain/canopy to the end limit of
the direction in which you wish to increase
the operating range.
First press the programming button and,
within 3 seconds, also press the STOP but-
ton and keep both buttons pressed for 10
seconds.
Move the curtain/canopy to the desired new
end limit.
First press the programming button and,
within 3 seconds, also press the EXTEND
button for the lower end limit or the RE-
TRACT button for the upper end limit and
keep both buttons pressed.
7) Deleting the end limits
Note
The end limit settings can only be deleted using the master transmitter.
7a) Deleting the end limits individually
Move the curtain/canopy to the end limit to
be deleted.
First press the programming button and,
within 3 seconds, also press the STOP but-
ton and keep both buttons pressed for 10
seconds.
22
Operating Instructions
Response
The tubular drive makes a „clack" sound to
confirm.
The new end limit is stored.
The tubular drive makes a „clack-clack"
sound to confirm.
The end limit has been deleted.
The tubular drive makes a „clack" sound to
confirm.
The new end limit has been stored.
The tubular drive makes a „clack-clack"
sound to confirm.
The end limit has been deleted.