not mentioned in this instruction
manual may only be performed
by our service centre. Many acci-
dents are caused by poorly maintained
appliances.
• Only use accessories recom-
mended by PARKSIDE. Unsuitable
accessories may cause electric shock
or fire.
Residual risks
There will always be residual risks even
if you operate this power tool according
to the instructions. The following hazards
may occur in connection with the type and
design of this power tool:
• Eye damage if no suitable eye protec-
tion is worn.
• Hearing damage if suitable ear protec-
tion is not worn.
• Health injuries resulting from the effect
of vibration on the hands and arms in
the event that the device is used over
a longer period of time or is not used
and maintained properly.
• Cutting injuries
 WARNING! Danger due to electro-
magnetic field generated while the ma-
chine is in operation. Under certain cir-
cumstances, this field may negatively af-
fect active or passive medical implants.
In order to reduce the danger of serious
or fatal injuries, we recommend that indi-
viduals who wear medical implants should
consult their doctor and the manufacturer
of the implant before operating the ma-
chine.
Preparation
 WARNING! Risk of injury due to
unintentional start-up. Only insert the re-
chargeable battery into the device once
the device is fully prepared for use.
34
Control elements
Familiarise yourself with the operating ele-
ments before using the device for the first
time.
• On/Off switch (13)
• Switching the device on or off
• When released, the device switches
off immediately.
• Switch lock (11)
To protect against accidental switch-on,
the switch lock must be locked.
• Lock (5)
Unlocks/locks the telescoping of the
extension arm.
• Locking button (3)
Locks/unlocks the angle adjustment of
the motor head.
Attaching and removing the
tubular shaft
Requirements
• Battery removed.
Attaching the tubular shaft
(Fig. A)
1. Insert the tubular shaft (16) into the
threaded coupling (26).
2. If necessary, turn the tubular shaft (16)
so that the lug (27) engages in the re-
cess on the threaded coupling (26).
3. Tighten the coupling nut (7) onto the
threaded coupling (26).
Removing the tubular shaft
(Fig. A)
1. Unscrew the coupling nut (7) from the
threaded coupling (26).
2. Pull the tubular shaft (16) off the
threaded coupling (26).
Attaching and removing the
motor head
Requirements
• Battery removed.