Herunterladen Diese Seite drucken

RAVAGLIOLI KPX55LIKTA Originalanleitung Seite 73

2 säulen hebebühne

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 85
INDEX
8.5 SYNCHRONISATION CONTROL DEVICE OPERATION.
Warning!
Checks and emergency procedures must be carried out by a specialised technician due to the presence of
electrical voltage.
The panel contains an electronic board (1) equipped with a LED (2) that stays lit when the switch is in the conditions described below:
Control box switch part no. 047303120 - 047303130
1
1
1
• Electric circuit activated
2
2
2
0
0
0
• TEqLINK activated
• Push-buttons (4) and (5) deactivated
1
1
1
• TEqLINK activated
2
0
2
0
2
• Lockable position
Problem: lift blocked (acoustic warning).
Solution: emergency down stroke possible (single down movement).
- If the lift is blocked, it is possible to lower the carriages.
model
1
- Turn to
2
0
0
- Remove the cover of the electric box.
- Move lever (3) downwards in manual mode (A).
model
1
1
- Turn to
2
2
0
0
0
Single down movement of carriages. Activate the down stroke control
- push-button P1 to move the carriage of the control column; push-button P2 to move the carriage of the opposite column.
1
EN_28
0473-M003-0
1
1
2
2
0
1
2
P2
model
P1
2
B
3
A
KPX55LIKTA - KPX55ELIKTA
and simultaneously press:
4
5

Werbung

loading

Diese Anleitung auch für:

Kpx55eliktaRav.kpx55.198945Rav.kpx55.198976