Herunterladen Inhalt Inhalt Diese Seite drucken

Becker ronic TimeControl Montageanleitung Und Bedienungsanleitung Seite 67

Zeitschaltuhr fur lichtsensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

FUNCTION (only when the control panel is detached, for
qualified technicians only)
ROLLER SHUTTER/VENETIAN BLIND, DRIVE CONTROLLER/GROUP
CONTROLLER, RUNNING TIME
(selection of the shading solution, selection as drive controller/group control-
ler, running time of roller shutter/venetian blind)
AUTO
RUNNING TIME
1.
Press the MENU button.
2.
To select the FUNCTION menu, press the + button until FUNCTION ap-
pears.
3.
Confirm with OK. ROLLER SHUTTER/VENETIAN BLIND appears.
4.
You can choose between roller shutter/venetian blind using the +/- but-
tons.
5.
Confirm with OK. DRIVE CONTROLLER/GROUP CONTROLLER appears.
6.
You can select the required setting using the +/- buttons (DRIVE CON-
TROLLER/GROUP CONTROLLER).
7.
Confirm with OK. RUNNING TIME appears.
8.
You can set the necessary running time using the +/- buttons. (Preset-
ting: 120 seconds for roller shutters and 180 seconds for venetian
blinds).
9.
Confirm with OK.
10. The RUNNING TIME function is now set.
11. For details on further programming in the FUNCTION menu, please con-
tinue reading.
FUNCTION
ROLLER SHUTTER
DRIVE CONTROLLER
67 - en