ADJUSTING OVEN GAS CONTROL VALVE MINIMUM SETTING
Important
This adjustment is only required if the type of
gas to be connected is different from that
used for testing after the conversion proce-
dure has been carried out (see page 15).
To carry out this operation,
proceed as follows.
1 - Turn off the gas supply
tap.
2 - Pull off the knobs (A).
3 - Undo the screws (B)
and remove the control
panel (C).
4 - Remove the injector (D)
and replace it with the
one suitable for
the type of gas in
use (see table at
back of manual).
N.B.: after making the setting, seal the screw with
paint.
5 - Replace the control panel (C) and the knobs (A)
on completion of the operation.
IT
GB
ADJUSTING TOP BURNER PRIMARY AIR
1 - Turn off the gas supply
DE
tap.
2 - Pull off the knob (A).
FR
3 - Undo the screws (B) and
remove the control panel
(C).
ES
4 - Undo the screw (D) and
lift the burner support (E)
as far as it will go.
5 - Tighten the screw (D) and
restore the initial condi-
tions when the operation
is complete.
English
Before making this adjustment, check that
the gas supply pressure is the same as the
rated pressure for the type of gas in use (see
table at back of manual).
B
C
A
B
C
A
- 18 -
D
IDM-39609301100.tif
E
D
IDM-39609301300.tif