Important safety instructions
en
Save these instructions
Safety rules
A B B U P S P R O D U C T S A N D S O L U T I O N S
This manual contains important instructions that
should be followed during installation and
maintenance of the UPS. It also gives all necessary
information about the correct use of the UPS.
Before attempting to install and switch the UPS
on, carefully read this manual. Keep this manual
next to the unit for future reference.
Full understanding of and
compliance with the safety
instructions and warnings contained
in this manual are the
ONLY CONDITIONS
to avoid any dangerous situation
during installation, operation and
maintenance work, and to ensure
the maximum reliability of the UPS
system.
CAUTION! RISK OF ELECTRIC SHOCK
THE UPS CONTAINS BATTERIES. THE
APPLIANCE OUTLETS MAY BE
ELECTRICALLY LIVE, EVEN WHEN THE UPS
IS DISCONNECTED FROM THE MAINS.
THE UPS CONTAINS POTENTIALLY
DANGER
HAZARDOUS VOLTAGES. DO NOT OPEN
THE MAIN UNIT ENCLOSURE; THERE ARE
NO USER SERVICEABLE PARTS INSIDE.
THE BATTERIES ARE REPLACEABLE BY
THE USER AND ACCESSIBLE BY THE
WARNING
BOTTOM REMOVABLE COVER (SEE
DEDICATED CHAPTER).
THIS IS A CLASS C2 UPS PRODUCT. IN A
RESIDENTIAL ENVIRONMENT, THIS
PRODUCT MAY CAUSE RADIO
INTERFERENCE, IN WHICH CASE THE USER
MAY BE REQUIRED TO TAKE ADDITIONAL
WARNING
MEASURES
• The UPS is intended to be used in normal
domestic and office situations.
• The branch circuit supply has to be protected
with a 16A building fuse.
ABB shall not be liable in case of non-observance,
unauthorised alterations or improper use of the
delivered UPS.
The instructions in this manual are for UPS
models PowerValue 11 LI Pro 600VA, PowerValue
11 LI Pro 800VA, PowerValue 11 LI Pro 1000VA,
PowerValue 11 LI Pro 1500VA and PowerValue 11 LI
Pro 2000VA. You can find the model name on the
product label of your UPS.
While every care has been taken to ensure the
completeness and accuracy of this manual, ABB
accepts no responsibility or liability for any loss
or damage resulting from the use of the
information contained in this document.
• The UPS must be powered from a single-phase
grounded wall outlet. This wall outlet must be
easily accessible and close to the UPS. Do not
use extension cords.
• Place cables in such a way that no one can step
on or trip over them.
• Avoid locations that are excessively humid, near
water, near heat sources or in direct sunlight.
• The ambient temperature should not exceed
40°C. optimal battery lifetime is obtained if the
ambient temperature does not exceed 30°C.
• It is important that ventilation air can move
freely around and through the unit. Do not
block the air vents.
• The UPS output can be used only for electronic
loads such as computers and
telecommunications equipment. Life support
or critical medical equipment should not be
connected. Do not plug household appliances
such as electric heaters, toasters and vacuum
cleaners into the UPS.