Installation and Operating Instructions
EN
m
DANGER
m
DANGER
NOTE
ATTENTION
ATTENTION
NOTE
Central ventilation units AIR1 XVP
batteries and accumulators. You can return batteries and accumulators free of charge to retailers or municipal collection points.
Batteries or rechargeable batteries that contain harmful substances are marked with a crossed-out dustbin symbol.
Under the garbage can symbol is the chemical designation of the pollutant.
Cd for cadmium / Pb for lead / Hg for mercury
Think of our environment, with the return you make a substantial contribution to environmental protection!
24
Mechanical assembly
m
Danger to life due to electric shock!
The installation and connection of the unit may only be carried out by qualified specialist personnel. The electrical con-
nections must be carried out by a person who has proper professional training and experience in the relevant accident
prevention regulations, as well as other generally recognised safety and occupational health codes, with authorisation
to perform work on the unit.
Risk of injury due to electric shock, hot surfaces and potentially hot surface of optional auxiliary heater
m
Danger to life due to electric shock!
The unit must be fully isolated from the mains power supply before all maintenance and installation work and
opening the terminal compartment! The electrical connections must be carried out in accordance with the
relevant wiring diagram and must only be carried out by qualified electricians The electrical connection must
be fully isolated until the final assembly!
241 General mechanical assembly
The central ventilation unit AIR1 XVP.. must be installed in the upright position. Due to noise levels, which change
depending on system pressure, it is recommended that the compact ventilation unit is installed in the utility room or
storage room. It must be ensured that there is a waste water connection in the installation area. In this respect, please
consider the condensation outlet information!
The assembly should take place in such a way to enable the shortest possible ventilation ducts and trouble-free con-
nection to the unit. Tight bends result in increased pressure losses and flow noises.
The unit can be turned 180° for optimal installation, so that the inlets and outlets for the outside air/exhaust air and
extract air/supply air can be on the left or right side of the unit. With regard to these properties, bends and long pipe
sections are not required. In addition, the heat loss is reduced and the system efficiency is increased.
Important note:
– The ventilation ducts must not become kinked.
– The connections to the connectors must be firm and tight.
– The flange connections must be leakproof and firm.
– If necessary, anti-vibration mounts can be used on site between the base of the unit and the floor.
Ensure that the unit is positioned on a flat surface before the start of installation work.
Assembly area
The AIR1 XVP.. ventilation units are exclusively intended for installation in frost-free indoor spaces
(room temperature > 0 °C).
The following criteria must be observed when installing the unit to ensure easy accessibility for maintenance and main-
tenance work (Fig.4).
A: Minimum distance for servicing above the unit
B: Depth of unit
C: Minimum distance for servicing in front of the unit
D: Height of unit (incl. terminal box)
B
It must be ensured that there is sufficient space for the maintenance work For this reason, the dimensions
must first be marked before the unit is assembled
Gerätetyp
The installation of accessory parts is easier prior to the final positioning and installation of the unit, since access is
AIR1 XVP
A
possible on both sides.
AIR1 XVP 850
200
785
AIR1 XVP 1250
200
755
AIR1 XVP 1800
200
885
AIR1 XVP 2500
200
926
AIR1 XVP 3500
200
1122
Maß festgelegt Geräte Maß D Geräte Maß D
Gerätemaße
C
Maße in mm
B
C
D
985
1596
955
1723
1085
1864
1126
2004
6
1322
2128
Geräte Maß max. E
+ 200 mm
Type
A (mm) B (mm) C (mm) D (mm)
200
785
AIR1 XVP 850
AIR1 XVP 1250
200
755
AIR1 XVP 1800
200
885
AIR1 XVP 2500
200
926
AIR1 XVP 3500
200
1122
Fig4
1085
1596
1085
1723
1185
1864
1226
2004
1422
2128