The side outlet can also be used, proceed as follows:
1.
Remove the plug on the connector.
2.
Mke a 32/35 mm diameter hole in the side of the system's wall.
3.
Rmove the flexible pipe from the vertical position and after having sealed it, screw it in the
horizontal position.
4.
Pace the plug into the hole where the flexible pipe was fitted.
WARNING
Ideally an on-off valve should be fitted before the float valve so that the mains water can be turned off
in the event of breakage or malfunction, and so that maintenance can be performed in total safety.
4.6 Level switch installation (float)
Electrical layout - page 3-4
4.6.1 Electromechanical float version (ON/OFF float version):
1.
Position the float as indicated in figure 04.
2.
The counterweight should ideally be fitted at least 20 cm above the float.
3.
After having fitted the float, make sure that the cable is protected and made safe along its entire
length.
4.
Pass the cable through the lower hole of the system (the hole where all the pipes and power
cables pass, pos. 16 fig. 01, page 39).
5.
Connect the wires to the terminals IN1 and +V1. No polarity, see fig. 05, page 47.
6.
Clamp the cable to the internal pipes of the equipment.
7.
The float switch must change the contact at least 15 cm before the foot valve (pump suction
valve) takes in air.
ENGLISH
Figure 04
Float switch
Bottom of the tank
48
Suction pipe

Werbung