Connection of condensate inlet
ED3002 and ED3004 are equipped with a top condensate inlet only, while
models ED3007, ED3030 and ED3100 have a revolving top inlet and a bottom
inlet for condensate.
Note:
For installation, we recommend using the appropriate installation
kit consisting of a ball valve with fittings.
Use open-ended spanner!
Never turn the condensate
drain to install it into the
pipeline! Always use an
open-ended spanner to
install the condensate drain.
Installation of ED3002
► Ensure that the drain is in vertical position (maximum permissible deviation
from perpendicular: +/- 5 %).
The integrated vent ensures proper condensate inlet and outlet.
Installation of ED3004, ED3007, ED3030 and ED3100
► Turn the upper inlet piece to the desired position:
► Select the condensate inlet to be used.
► Ensure that the drain is in vertical position (maximum permissible deviation
from perpendicular: +/- 5 %).
► Connect condensate inlet to feed line. Install vent line, if required.
► Check connections for leakage.
Connection of condensate outlet
The condensate drain delivery includes a 8-10 mm hose tail.
Note:
 The water column in the condensate outlet should not exceed 2 m.
 The condensate outlet lines should not be pressurized but open.
► Connect the condensate outlet to the condensate drain line.
ED3002–ED3100_Int-1_08
Pull pin.
Turn inlet piece.