Elektronischer kondensatableiter

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN / Operating instructions
Function
The condensate enters the unit through the inlet (1 or 2) and collects in the
collecting chamber (3). When the collecting chamber is completely filled with
condensate (4), the condensate is drained through the outlet (5) until the
chamber is emptied. An integrated flow regulator (6) prevents a pressure bang
when the valve is opened, ensuring smooth and noise-free drainage of the
condensate.
Depending on the size, a LED signals in the colors green, green/red flashing and
red (ED3002 – ED3004) or green, orange and red (ED3007 - ED3100) the
different conditions of the drain. A green LED indicates normal and trouble-free
operation.
A red/green flashing (ED3002 – ED3004) or constantly orange LED (ED3007 -
ED3100) indicates that no condensate has been drained for a period of 15 hours.
After condensate has been drained off, the LED changes to green.
The LED flashes slowly in red, if the condensate cannot be drained off within the
set time and an internal cleaning program has been started. After successful
cleaning the drain returns to normal operating mode. If the cleaning program
cannot be completed successfully. an emergency program is started and an
alarm signal is issued (LED flashing rapidly in red).