Parker Ecodrain ED-Serie Bedienungsanleitung Seite 20

Elektronischer kondensatableiter

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN / Operating instructions
Observe gradient in flow
direction!
Ensure a proper gradient of
the inlet line. Otherwise, air
bubbles might prevent
condensate from entering
the drain.
Install vent line!
If the bottom condensate
inlet is used, install a vent
line. Otherwise, air bubbles
trapped in the collecting
chamber might prevent
condensate from entering
the chamber.
Observe levels!
The switching level of the
condensate drain must be
lower than the vessel.
Otherwise, condensate
might be backed up in the
vessel.
Prevent carry-over of
condensate!
Straight pipelines might
lead to carrying over of
condensate. Install suitable
condensate traps.
20
incorrect
incorrect
incorrect
incorrect
ED3002–ED3100_Int-1_08
correct
correct
correct
correct