Technical data
Ambient temperature limits
!
Storage temperature
Electrical safety
Climate class
Degree of protection
Shock and vibration resistance
Condensation
Installation category
Pollution degree
Electromagnetic compatibility
(EMC)
Design, dimensions
62
12.0.6
Environment
-40 to +80 °C (-40 to +176 °F)
Note!
The display can react slowly for temperatures < -20 °C (< -4 °F).
Readability of the display cannot be guaranteed at temperatures < -30 °C (-22 °F).
-40 to +85 °C (-40 to +185 °F)
As per IEC 61010-1,
UL61010-1,
CSA C22.2 No. 1010.1-92
As per IEC 60 654-1, Class C
IP 67, NEMA 4X
3g / 2 to 150 Hz as per IEC 60 068-2-6
Permitted
1 to IEC 61010
2 to IEC 61010
• EN 61326 (IEC 61326):
Electromagnetic compatibility (EMC requirements)
• NAMUR (NE21):
Association for Standards for Control and Regulation in the Chemical Industry
12.0.7
Mechanical construction
Fig. 16:
Data in mm (data in inches in brackets)
• Die cast aluminum housing for general purpose or as option stainless steel housing
• Electronics compartment and connection compartment together in the single chamber housing
• Display can be rotated in 90°-stages