The display can be turned in stages of 90°. First remove the cover clamp (1) and the housing cover
(2). Then remove the display (3) from the electronics unit (4). For configuration purposes, plug in
the ribbon cable between the display and electronics unit. After configuration, the cable can be
removed.
Turn the display to the desired position and then attach it to the electronics unit.
Note!
The connecting cable (ribbon cable) between the display and electronics unit can be disconnected
after configuration.
4.2
Installation conditions
4.2.1
Dimensions
Fig. 4:
Installation dimensions; dimensions in mm (dimensions in inches in brackets)
4.2.2
Installation location
Information on conditions that must be present at the installation location to mount the device
correctly can be found in Section 12 'Technical data'. These include the ambient temperature,
degree of protection, climate class etc.
4.3
Mounting
4.3.1
Direct wall mounting
Proceed as follows to mount the device directly on the wall:
• Drill 2 holes
• Attach the device to the wall with 2 screws (M6).
4.3.2
Pipe mounting
The mounting bracket is suited for pipes with a diameter between 1.5" - 3.3".
Proceed as follows to mount the device on a pipe:
• Attach the mounting bracket to the pipe
• The additional mounting plate must be used for pipes with a diameter of 1.5" to 2.2".
• Fix the device to the mounting bracket with the two screws supplied. The mounting plate is not
needed for pipes with a diameter of 2.2" - 3.3".

Werbung