Herunterladen Diese Seite drucken

HBM T40FM Montageanleitung Seite 83

Vorschau ausblenden Andere Handbücher für T40FM:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Nominal (rated) torque M
At positive nominal (rated)
torque
At negative nominal (rated)
torque
Maximum modulation range
invalid measured value
Load resistance
Residual ripple
Temperature effect per 10 K in
the nominal (rated) temperature
range
on the output signal, related to
the actual value of the signal
span
on the zero signal, relative to
the nominal (rated) sensitivity
Long-term drift over 48 h at refer­
ence temperature, related to the
nominal (rated) sensitivity
Rotational speed measuring system
Measurement system
Magnetic poles
Maximum positional variation of
the poles
Output signal
Pulses per revolution
Minimum rotational speed for
sufficient pulse stability
T40FM
nom
2
3)
A3276-8.0 HBM: public
Order numbers, Accessories
kNVm
15
20
kHz
kHz
V
V
mV
%
%
%
Magnetic, via AMR sensor (Anisotropic
Resistive Effect) and magnetized
plastic ring with embedded steel ring
158
"50 angular seconds
V
5 V symmetrical (RS-422);
2 square-wave signals, approx. 90_
rpm
25
30
40
50
10
-10
"12
13 ... 15
>10
<40 (peak-to-peak)
0.2
<"0.15
<"0.03
186
phase-shifted
1024
0
60
70
80
204
81

Werbung