After Use
1
Raise the brushes (or pads) and raise the squeegee. Move the machine to a service area.
2
Turn the Master Key Switch (11) OFF and remove the key.
3
To empty the solution tank, take the Solution Drain Hose off its hanger. Direct the hose to a floor drain or bucket and remove the plug.
Rinse the tank with clean water. Inspect the solution hoses; replace if kinked or damaged.
4
To empty the recovery tank, take the Recovery Drain Hose (12) off its hanger. Direct the hose to a floor drain or bucket and remove the
plug. Rinse the tank with clean water. Inspect the recovery and vacuum hoses; replace if kinked or damaged.
5
Remove the brushes or pad holders. Rinse the brushes or pads with warm water and hang it up to dry. Allow buffing pads to dry completely
before using again.
6
Remove the squeegee, rinse it with warm water and hang it up to dry.
7
Check the maintenance schedule below and perform any required maintenance before storage.
Maintenance Schedule
Clean Vacuum Shut-Off Float
Check Battery Electrolyte Level
*Have Nilfisk check the carbon motor brushes once a year or after 300 operating hours.
8
Store the machine in a clean, dry place.